AcquCAM 23GR2

가시광선 및 근적외선 대응 칼라 카메라

Sample : bovine pulmonary artery endothelial cell, BPAEC
Camera : AcquCAM 23GR2 , Fluorescence Filter Set : JNO-U(B), B(B), G(B)
Objective lens:UPLNAPO40X, C-mount adapter : 1X
Above three images are merged and processed using JNO-ARM
AcquCAM 23GR2 fluorescence Image
OLYMPUS BX51, UPlanApo40x U-TV1XC JNOpTIC AcquCAM 23GR2, JNO-UBG(B) C TYPE
AcquCAM 23GR2 fluorescence Image
OLYMPUS BX51, UPlanApo40x U-TV1XC JNOpTIC AcquCAM 23GR2, JNO-UBG(B) B TYPE
  • USB 3.0 Color Camera
  • 1/1.2 ” Exmor Sensor
  • 1920×1200 pixel
  • Trigger input and I/O
  • Available  of taking images with a wavelength of 650nm or more, such as CY5
  • High Sensitivity Sensor (Best)
  • Fast, seamless image transfer
  • Available of images with a very wide field of view
  • Low Noise Sensor
     
     

The displays live digital images with gradual smoothness and combines exceptional resolution  with faithful color reproduction.The new sensors feature a global shutter function and able to capture a high-speed moving image without focal plane distortion. High-speed processing, low noise and low power dissipation by using column-parallel A/D conversion. equipped with trigger mode, and the external pulse can control accumulation time. The Sensor also have a pulse output function to indicate respective conditions during shutter operation and can be coordinated with peripheral circuits. High-definition images can be displayed live at a rate of high frames per second. without compression. Such imaging quality enables even the finest cellular regions to be observed clearly and distinctly without deterioration. While focusing is made stress free.

Images with AcquCAM 23GR2

Sample : bovine pulmonary artery endothelial cell, BPAEC
Filter Set : JNO-U(B), B(B), G(B)
Camera : AcquCAM 23GR2
C-mount adapter : 1X
Lens : UPLNAPO40X
Above three images are merged and processed using ARM S/W

JNO-ARM

Advance Realtime Monitor. Easy-to-Use, Image Enhancement, etc

1. Information

ARM is image analysis software for JNOPTIC AcquCAM cameras. This S/W is interchangeable with all WDM cameras regardless of camera brand and model and even more the most strength point is simple and easy use of length, area, angle, etc.

2. Simple measurement tools

  • Measurement Tools: Count, Distance, Angle, Area, etc.
  • Guide Lines: Cross Line, Rectangular Lattice, Circular Grid
  • Scale Panel on Live/Image Screen
  • Available measurement on LIVE image and saved image mode

3-1. Specialization for observation of fluorescence images

Improvement Function about Fluorescence Microscopy Image. (Used function: Auto Level, Low level, Pseudo Color, Merge Image)

Bottom on the left is merged image without improvement of image. And the bottom on the right is merged image after improvement of image. These images are shot by JNOPTIC AcquCAM Pro/G3 camera

3-2-1 Effect of high-contrast image with simple operation (Monochrome)

Improvement Function about Microscopy Image Monochrome. (Used function: Auto Level)

Effective improvement of image with simple operation. This image is shot by JNOPTIC Pro/S3 camera

3-2-2 Effect of high-contrast image with simple operation (Color)

Improvement Function about Microscopy Image. (Used function: Auto Level)

Effective improvement of image with simple operation. These images are shot by JNOPTIC AcquCAM Pro/G3 camera

3-3-1 Live Pseudo Color (for color camera)

When you get fluorescence images using color camera, if the unwanted channel was shown because of cross talk, you could remove this channel to take advantage of function of Live Pseudo.
Improvement Function about Fluorescence Microscopy Live Camera Image. (Used function: Live Pseudo Color)
 The extraction of wanted color information from color image (Remove BR on RGB source) These images are shot by JNOPTIC AcquCAM Pro/G3 camera
 
 
 

 

3-3-2 Live Pseudo Color (for Monochrome camera)

When you get fluorescence images using monochrome camera, you can raise efficiency of acquisition for fluorescence images to add similar false color to the color to be shown on the eyepiece in real time.
Improvement Function about Fluorescence Microscopy Live Monochrome Camera Image. (Used function: Live Pseudo Color)
 Improvement of usage environment for monochrome camera to add false color on the image. These images are shot by JNOPTIC AcquCAM Pro/S3 camera
 
 

 

4. JNO-MHU(Option Unit)

Available measuring height with additional unit, JNO-MHU

※ JNO-MHU is sold separately as optional unit.

Left: Focus on top of sample (Z-axis reset), Right: Focus on bottom of sample (Z-axis height measurement)

 < Measuring condition : over 20x objective, temp 20°C >

 
Responding Model Measurement value unit Measurable height Error of measuring 1000㎛ Recommended measuring height
CX 41 0.2 ㎛ -9.9 ~ 29.9㎜ Below ±20㎛ Below ± 2000㎛
CKX 41 0.2 ㎛ -9.9 ~ 29.9㎜ Below ±20㎛ Below ± 2000㎛
BX – FM 0.2 ㎛ -9.9 ~ 29.9㎜ Below ±20㎛ Below ± 2000㎛
BX 51/53 0.1 ㎛ -9.9 ~ 29.9㎜ Below ±10㎛ Below ± 1000㎛
MX 51 0.1 ㎛ -9.9 ~ 29.9㎜ Below ±10㎛ Below ± 1000㎛
MX 61L/61 0.1 ㎛ -9.9 ~ 29.9㎜ Below ±10㎛ Below ± 1000㎛

5. Reporting to Excel

Specification

Spec Description
Size 1/1.2 inch
Resolution H: 1920, V: 1200
Pixel size H: 5.86 µm, V: 5.86 µm
Video formats& Frame rate 1920×1200 RGB24@ 54 fps
1920×1200 Y800@ 162 fps
1920×1200 Y16@ 80 fps                             1920×1200 Y411 @ 108 fps
1920×1200 YUY2 @ 81 fps
Dynamic range 8 / 12 bit
Exposure time 20 ㎲ to 30s
Lens mount C/Cs mount
Interface USB 3.0
Power supply 4.5 to 5.5 VDC
Dimensions H: 29 mm, W: 29 mm, L: 43 mm
Mass 65g

More images with AcquCAM 23GR2

-> For more details, click here.

AcquCAM 5G

AcquCAM 5G

 

Down load Catalog – ACQUCAM 5G

 

  • USB 3.0 Color Camera
  • 2/3 ” Pregius Sensor
  • 2448 x 2048 pixel
  • Trigger input and I/O
  • Acquisition of images with sufficient contrast
  • High Sensitivity Sensor
  • Fast, seamless image transfer
  • Available of images with a very wide field of view
  • Low Noise Sensor

 

AcquCAM 5G color camera has a USB 3.0 interface and is the perfect solution for many industrial automation, quality assurance, security, surveillance and medical applications. The color camera ships with the very sensitive 2/3 inch CMOS Pregius  sensor. With up to 38 images per second, the AcuqCAM 5G is a low cost, yet highly versatile imaging solution. The camera includes a C to CS mount adapter, making it compatible to C and CS mount lenses. Using the optional CS to M12 board lens adapter, the camera is
also compatible to M12 board lenses.

 

 

Images with AcquCAM 5G

 

Sample : bovine pulmonary artery endothelial cell, BPAEC
Filter Set : JNO-U(B), B(B), G(B)
Camera : AcquCAM 5G
C-mount adapter : 1X
Lens : UPLNAPO40X
Above three images are merged and processed using ARM S/W

 

Specification

Spec Description
Size 2/3 inch
Resolution H: 2448, V: 2048
Pixel size H: 3.45 µm, V: 3.45 µm
Video formats& Frame rate 2448×2048 RGB64 @ 38 fps
2448×2048 RGB32 @ 35 fps
2448×2048 Y16 @ 37 fps                             2448×2048 Y411 @ 38 fps
2448×2048 YUY2 @ 37 fps
Dynamic range 8 / 12 bit
Exposure time 25 ㎲ to 4s
Lens mount C/Cs mount
Interface USB 3.0
Power supply 4.5 to 5.5 VDC
Dimensions H: 29 mm, W: 29 mm, L: 43 mm
Mass 65g

 

ARM

ARM is image analysis software for JNOPTIC AcquCAM cameras. This S/W is interchangeable with all WDM cameras regardless of camera brand and model and even more the most strength point is simple and easy use of length, area, angle, etc.

-> For more details, click here.

More images with AcquCAM 5G

-> For more details, click here.

 

AcquCAM 5Gtemp

AcquCAM Pro/G3

가장 저렴한 가격의 형광현미경용 칼라 카메라

특성을 표현 할 수 있는 이미지 모음 준비

AcquCAM Pro/S3

가장 저렴함 가격의 형광현미경용 흑백 카메라

칼라 카메라보다 3배 좋은 형광 감도

생리학교실 전용 카메라

특성을 표현 할 수 있는 이미지 모음 준비

 

AcquCAM 3G

비용대비 최고의 효율의 칼라 카메라

특성을 표현 할 수 있는 이미지 모음 준비

 

AcquCAM 5G

넓은 영역을 찍을 수 있는 칼라 카메라

특성을 표현 할 수 있는 이미지 모음 준비

 

AcquCAM 23GR2

CY5와 같이 650㎚이상의 파장의 이미지를 찍을 수 있는 카메라

특성을 표현 할 수 있는 이미지 모음 준비

 

AcquCAM 23S2

가성비 최고의 형광현미경용 흑백카메라

가성비 최고의 생리학교실용 카메라

1/1.2inch로 현미경시야에 최적화된 센서 사이즈

0.63x의 카메라 아답터와 조합시에 최적의 넓이의 이미지를 획득할 수 있습니다.

특성을 표현 할 수 있는 이미지 모음 준비

 

 

TOMORO AcquCAM 3

TOMORO AcquCAM 3

 

TOMORO ACQUCAM 3는  현미경 영상 획득을 위해 설계되었습니다.

3백만 화소의 이미지 소자는 현미경 영상을 대한 최적화 된 솔루션을 제공합니다.

USB2.0 인터페이스를 통하여 하나의 케이블 연결만으로 300만화소의 이미지를 초당 10 프레임으로 관찰 할 수 있으며 최대 35.5 프래임의 고속으로도 현미경 영상을 관찰할 수 있습니다.

Features

* 3 Mega pixel Micron MT9T031 CMOS Sensor

* Color, Progressive scan

* High Speed USB 2.0 Interface (480Mbits/sec)

* 10  fps at 2560×1536 resolution  /  up to 35.5 fps at 1024×768 resolution

* Auto White Balance support

* RGB Bayer video output

* Hot pluggable

* All camera parameters adjustable via the computer

* Preview Software provided (TOMORO Capture)

* Software compatible with Windows 2K/XP and Vista (32/64bit)  operating systems

* Fully integrated with OLYMPUS ‘analySIS’ image analysis softare not TWAIN

 

Specifications

Sensor  Micron MT9T031
Type CMOS Progressive scan
Size 1/2 inch
Resolution H:2560, V:1536
Pixel size H:3.2um, V:3.2um
Video formats &(Frame rates) 10 Fps at Full resolution
Up to 35.5 Fps at XGA (1024×768) resolution
Sensitivity 5 lx at 1/30s, gain 20 dB
Exposure time 100us  to 2sec
White balance Auto / Manual
Lens mount C/Cs mount
Interface Mini USB 2.0 interface 480Mbit/s
Power supply 4.5 to 5.5  VDC via USB 2.0
Dimensions H:50.6mm, W:50.6mm, L:29mm
Mass Approx 140g