Standard Filter

Standard FilterFluorescence Filter Sets

형광시약에 폭넓게 대응이 되는 기본 형광 필터 세트
– U, G, B Excitation(자극)
– Long-Pass or Band-Pass Emission

기본 형광 필터 세트              – Best Selling Product –
Standard Fluorescence Filter Cube Set for Microscope
Standard Fluorescence Filter Cube Set, Band Pass type
JNO-U(B),   JNO-B(B),   JNO-G(B) – Made by JNOPTIC
39000, 39002, 39004 – Chroma Filter Model No.

기본 형광 필터 세트의 세부정보는 제품의 모델명을 클릭하시면 확인하실수 있습니다.

DAPI Filter Set : JNO-U(B)

  • JNO-U(B) filter set induces the light of the UV wavelength range to the sample and leads the generated fluorescence to the observation system.
  • UV excitation (Bandpass Emission)
  • EX : 361~389, BS : 415, EM : 435~485
  • Chroma filter 모델 No. 로 확인 시 39000 참고
  • DAPI VS JNO-U(B)

DAPI Filter Set : JNO-U(L) 

  • JNO-U(L) filter set induces the light of the UV wavelength range to the sample and leads the generated fluorescence to the observation system.
  • UV excitation (Longpass Emission)
  • EX : 361~389, BS : 415, EM : 435
  • Chroma filter 모델 No. 로 확인 시 19000 참고
  • DAPI VS JNO-U(L)

FITC Filter Set : JNO-B(B) 

  • JNO-B(B) filter set induces the light of the Blue wavelength range to the sample and leads the generated fluorescence to the observation system.
  • Blue excitation (Bandpass Emission)
  • EX : 465~495, BS : 505 EM : 515~555
  • Chroma filter 모델 No. 로 확인 시 39002 참고
FITC VS JNO-B(B)

FITC Filter Set : JNO-B(L)

  • JNO-B(L) filter set induces the light of the Blue wavelength range to the sample and leads the generated fluorescence to the observation system.
  • Blue excitation (Longpass Emission)
  • 465~495, BS : 505, EM : 515
  • Chroma filter 모델 No. 로 확인 시 19002 참고
  • FITC VS JNO-B(L)

TRITC Filter Set : JNO-G(B) 

  • JNO-G(B) filter set iduces the light of the Green wavelength range to the sample and leads the generated fluorescence to the observation system.
  • Green excitation (Bandpass Emission)
  • EX : 527~553, BS : 565, EM : 577~633
  • Chroma filter 모델 No. 로 확인 시 39004 참고
TRITC VS JNO-G(B)

TRITC Filter Set : JNO-G(L) 

  • JNO-G(L) filter set iduces the light of the Green wavelength range to the sample and leads the generated fluorescence to the observation system.
  • Green excitation (Longpass Emission)
  • EX : 527~553, BS : 565, EM : 575
  • Chroma filter 모델 No. 로 확인 시 19004 참고
  • TRITC VS JNO-G(L)
    TRITC VS JNO-G(L)

AlexaFluor 594 Filter Set : JNO-R1(B) 

  • JNO-R1(B) filter set induces the light of the certain wavelength range to the sample and leads the generated fluorescence to the observation system.
  • Mirror unit for fluorescence microscopy (Bandpass Emission)
  • EX : 560~580, BS : 600, EM : 605~665
  • Chroma filter 모델 No. 로 확인 시 39010 참고
Alexa Fluor 594 VS JNO-R1(B)

Cy5 Filter Set : JNO-R2(B)

  • JNO-R2(B) filter set induces the light of the certain wavelength range to the sample and leads the generated fluorescence to the observation system.
  • Mirror unit for fluorescence microscopy (Bandpass Emission)
  • EX : 595~645, BS : 655, EM : 665~715
  • Chroma filter 모델 No. 로 확인 시 39007 참고
Cy5 VS JNO-R2(B)