Jae Hwan Jin의 모든 글

AcquCAM 5G Images

AcquCAM 5G

 

More images with AcquCAM 5G

 

Sample : bovine pulmonary artery endothelial cell, BPAEC
Filter Set : JNO-U(B), B(B), G(B)
Camera : AcquCAM 5G
C-mount adapter : 1X
Lens : PlanApo60xWLSM
Above three images are merged and processed using ARM S/W

 

Sample : bovine pulmonary artery endothelial cell, BPAEC
Filter Set : JNO-U(L), B(L), G(L)
Camera : AcquCAM 5G
C-mount adapter : 1X
Lens : UPLNAPO40X
Above three images are merged and processed using ARM S/W

 

 

AcquCAM 23GR2 Images

AcquCAM 23GR2

 

More images with AcquCAM 23GR2

 

Sample : bovine pulmonary artery endothelial cell, BPAEC
Filter Set : JNO-U(L), B(L), G(L)
Camera : AcquCAM 23GR2
C-mount adapter : 1X
Lens : UPLNAPO40X
Above three images are merged and processed using ARM S/W

 

Sample : bovine pulmonary artery endothelial cell, BPAEC
Filter Set : JNO-U(B), B(B), G(B)
Camera : AcquCAM 23GR2
C-mount adapter : 1X
Lens : PlanApo60xWLSM
Above three images are merged and processed using ARM S/W

 

 

 

 

 

AcquCAM 23GR2

가시광선 및 근적외선 대응 칼라 카메라

Sample : bovine pulmonary artery endothelial cell, BPAEC
Camera : AcquCAM 23GR2 , Fluorescence Filter Set : JNO-U(B), B(B), G(B)
Objective lens:UPLNAPO40X, C-mount adapter : 1X
Above three images are merged and processed using JNO-ARM
AcquCAM 23GR2 fluorescence Image
OLYMPUS BX51, UPlanApo40x U-TV1XC JNOpTIC AcquCAM 23GR2, JNO-UBG(B) C TYPE
AcquCAM 23GR2 fluorescence Image
OLYMPUS BX51, UPlanApo40x U-TV1XC JNOpTIC AcquCAM 23GR2, JNO-UBG(B) B TYPE
  • USB 3.0 Color Camera
  • 1/1.2 ” Exmor Sensor
  • 1920×1200 pixel
  • Trigger input and I/O
  • Available  of taking images with a wavelength of 650nm or more, such as CY5
  • High Sensitivity Sensor (Best)
  • Fast, seamless image transfer
  • Available of images with a very wide field of view
  • Low Noise Sensor
     
     

The displays live digital images with gradual smoothness and combines exceptional resolution  with faithful color reproduction.The new sensors feature a global shutter function and able to capture a high-speed moving image without focal plane distortion. High-speed processing, low noise and low power dissipation by using column-parallel A/D conversion. equipped with trigger mode, and the external pulse can control accumulation time. The Sensor also have a pulse output function to indicate respective conditions during shutter operation and can be coordinated with peripheral circuits. High-definition images can be displayed live at a rate of high frames per second. without compression. Such imaging quality enables even the finest cellular regions to be observed clearly and distinctly without deterioration. While focusing is made stress free.

Images with AcquCAM 23GR2

Sample : bovine pulmonary artery endothelial cell, BPAEC
Filter Set : JNO-U(B), B(B), G(B)
Camera : AcquCAM 23GR2
C-mount adapter : 1X
Lens : UPLNAPO40X
Above three images are merged and processed using ARM S/W

JNO-ARM

Advance Realtime Monitor. Easy-to-Use, Image Enhancement, etc

1. Information

ARM is image analysis software for JNOPTIC AcquCAM cameras. This S/W is interchangeable with all WDM cameras regardless of camera brand and model and even more the most strength point is simple and easy use of length, area, angle, etc.

2. Simple measurement tools

  • Measurement Tools: Count, Distance, Angle, Area, etc.
  • Guide Lines: Cross Line, Rectangular Lattice, Circular Grid
  • Scale Panel on Live/Image Screen
  • Available measurement on LIVE image and saved image mode

3-1. Specialization for observation of fluorescence images

Improvement Function about Fluorescence Microscopy Image. (Used function: Auto Level, Low level, Pseudo Color, Merge Image)

Bottom on the left is merged image without improvement of image. And the bottom on the right is merged image after improvement of image. These images are shot by JNOPTIC AcquCAM Pro/G3 camera

3-2-1 Effect of high-contrast image with simple operation (Monochrome)

Improvement Function about Microscopy Image Monochrome. (Used function: Auto Level)

Effective improvement of image with simple operation. This image is shot by JNOPTIC Pro/S3 camera

3-2-2 Effect of high-contrast image with simple operation (Color)

Improvement Function about Microscopy Image. (Used function: Auto Level)

Effective improvement of image with simple operation. These images are shot by JNOPTIC AcquCAM Pro/G3 camera

3-3-1 Live Pseudo Color (for color camera)

When you get fluorescence images using color camera, if the unwanted channel was shown because of cross talk, you could remove this channel to take advantage of function of Live Pseudo.
Improvement Function about Fluorescence Microscopy Live Camera Image. (Used function: Live Pseudo Color)
 The extraction of wanted color information from color image (Remove BR on RGB source) These images are shot by JNOPTIC AcquCAM Pro/G3 camera
 
 
 

 

3-3-2 Live Pseudo Color (for Monochrome camera)

When you get fluorescence images using monochrome camera, you can raise efficiency of acquisition for fluorescence images to add similar false color to the color to be shown on the eyepiece in real time.
Improvement Function about Fluorescence Microscopy Live Monochrome Camera Image. (Used function: Live Pseudo Color)
 Improvement of usage environment for monochrome camera to add false color on the image. These images are shot by JNOPTIC AcquCAM Pro/S3 camera
 
 

 

4. JNO-MHU(Option Unit)

Available measuring height with additional unit, JNO-MHU

※ JNO-MHU is sold separately as optional unit.

Left: Focus on top of sample (Z-axis reset), Right: Focus on bottom of sample (Z-axis height measurement)

 < Measuring condition : over 20x objective, temp 20°C >

 
Responding Model Measurement value unit Measurable height Error of measuring 1000㎛ Recommended measuring height
CX 41 0.2 ㎛ -9.9 ~ 29.9㎜ Below ±20㎛ Below ± 2000㎛
CKX 41 0.2 ㎛ -9.9 ~ 29.9㎜ Below ±20㎛ Below ± 2000㎛
BX – FM 0.2 ㎛ -9.9 ~ 29.9㎜ Below ±20㎛ Below ± 2000㎛
BX 51/53 0.1 ㎛ -9.9 ~ 29.9㎜ Below ±10㎛ Below ± 1000㎛
MX 51 0.1 ㎛ -9.9 ~ 29.9㎜ Below ±10㎛ Below ± 1000㎛
MX 61L/61 0.1 ㎛ -9.9 ~ 29.9㎜ Below ±10㎛ Below ± 1000㎛

5. Reporting to Excel

Specification

Spec Description
Size 1/1.2 inch
Resolution H: 1920, V: 1200
Pixel size H: 5.86 µm, V: 5.86 µm
Video formats& Frame rate 1920×1200 RGB24@ 54 fps
1920×1200 Y800@ 162 fps
1920×1200 Y16@ 80 fps                             1920×1200 Y411 @ 108 fps
1920×1200 YUY2 @ 81 fps
Dynamic range 8 / 12 bit
Exposure time 20 ㎲ to 30s
Lens mount C/Cs mount
Interface USB 3.0
Power supply 4.5 to 5.5 VDC
Dimensions H: 29 mm, W: 29 mm, L: 43 mm
Mass 65g

More images with AcquCAM 23GR2

-> For more details, click here.

AcquCAM 5G

AcquCAM 5G

 

Down load Catalog – ACQUCAM 5G

 

  • USB 3.0 Color Camera
  • 2/3 ” Pregius Sensor
  • 2448 x 2048 pixel
  • Trigger input and I/O
  • Acquisition of images with sufficient contrast
  • High Sensitivity Sensor
  • Fast, seamless image transfer
  • Available of images with a very wide field of view
  • Low Noise Sensor

 

AcquCAM 5G color camera has a USB 3.0 interface and is the perfect solution for many industrial automation, quality assurance, security, surveillance and medical applications. The color camera ships with the very sensitive 2/3 inch CMOS Pregius  sensor. With up to 38 images per second, the AcuqCAM 5G is a low cost, yet highly versatile imaging solution. The camera includes a C to CS mount adapter, making it compatible to C and CS mount lenses. Using the optional CS to M12 board lens adapter, the camera is
also compatible to M12 board lenses.

 

 

Images with AcquCAM 5G

 

Sample : bovine pulmonary artery endothelial cell, BPAEC
Filter Set : JNO-U(B), B(B), G(B)
Camera : AcquCAM 5G
C-mount adapter : 1X
Lens : UPLNAPO40X
Above three images are merged and processed using ARM S/W

 

Specification

Spec Description
Size 2/3 inch
Resolution H: 2448, V: 2048
Pixel size H: 3.45 µm, V: 3.45 µm
Video formats& Frame rate 2448×2048 RGB64 @ 38 fps
2448×2048 RGB32 @ 35 fps
2448×2048 Y16 @ 37 fps                             2448×2048 Y411 @ 38 fps
2448×2048 YUY2 @ 37 fps
Dynamic range 8 / 12 bit
Exposure time 25 ㎲ to 4s
Lens mount C/Cs mount
Interface USB 3.0
Power supply 4.5 to 5.5 VDC
Dimensions H: 29 mm, W: 29 mm, L: 43 mm
Mass 65g

 

ARM

ARM is image analysis software for JNOPTIC AcquCAM cameras. This S/W is interchangeable with all WDM cameras regardless of camera brand and model and even more the most strength point is simple and easy use of length, area, angle, etc.

-> For more details, click here.

More images with AcquCAM 5G

-> For more details, click here.

 

AcquCAM 5Gtemp

AcquCAM Pro/G3

가장 저렴한 가격의 형광현미경용 칼라 카메라

특성을 표현 할 수 있는 이미지 모음 준비

AcquCAM Pro/S3

가장 저렴함 가격의 형광현미경용 흑백 카메라

칼라 카메라보다 3배 좋은 형광 감도

생리학교실 전용 카메라

특성을 표현 할 수 있는 이미지 모음 준비

 

AcquCAM 3G

비용대비 최고의 효율의 칼라 카메라

특성을 표현 할 수 있는 이미지 모음 준비

 

AcquCAM 5G

넓은 영역을 찍을 수 있는 칼라 카메라

특성을 표현 할 수 있는 이미지 모음 준비

 

AcquCAM 23GR2

CY5와 같이 650㎚이상의 파장의 이미지를 찍을 수 있는 카메라

특성을 표현 할 수 있는 이미지 모음 준비

 

AcquCAM 23S2

가성비 최고의 형광현미경용 흑백카메라

가성비 최고의 생리학교실용 카메라

1/1.2inch로 현미경시야에 최적화된 센서 사이즈

0.63x의 카메라 아답터와 조합시에 최적의 넓이의 이미지를 획득할 수 있습니다.

특성을 표현 할 수 있는 이미지 모음 준비

 

 

PE-300ultra

 

CoolLED pE-300ultra

 

NOW DOUBLE THE INTENSITY AT THE SAMPLE PLANE

CoolLED’s pE-300ultra is a fluorescence microscopy light source which offers intense, broad-spectrum LED illumination for imaging most common fluorescent stains.  Users have access to both microsecond switching via multiple TTL inputs and the ability to mount inline excitation filters.  This, when paired with today’s high performance multi band filter sets, facilitates imaging traditionally done via a white light source and a filter wheel, with all the benefits of LED.

 

The pE-300ultra is the most controllable member of the pE-300 Series.  In addition to the many features of the pE-300lite and the pE-300white, the system offers precise control over wavelength intensity and shuttering.  Until now these benefits have only been accessible to users of high end, highly flexible illuminators such as the CoolLED pE-4000.

Throughout 2017 we will be releasing exciting new products and product updates.  The first member of the CoolLED product range to receive the star treatment is the pE-300 Series.

As part of the award winning pE-300 Series, the NEW Enhanced pE-300ultra  now delivers DOUBLE the intensity at the microscope sample plane.  It allows adjustment of output in 1% steps, giving precise control.  The broad spectrum covers everyday fluorophores: DAPI, CFP, Aqua, FITC, TRITC, TxRed, Cy5 and many more.

It is now possible to view and image your samples brighter than ever.

Convaleria taken with Photometrics Prime camera with 10ms exposure.

 

LED illumination means no mercury to dispose of and lower energy costs due to low power consumption and the precise control offered. With the new enhanced pE-300ultra, all 3 channels at full power use just 46 Watts. That is almost a quadruple efficiency increase!

This compares to other LED technology that uses 120 to 350 Watts. This leap forward in technology makes LEDs more attractive when compared to old Mercury or Metal Halide technology.  Where “green” funding is available, the reduction in institutional energy usage improves the return on investment.

CoolLED’s pE-300 Series  was the 2017 winner of the “Go Beyond Award” in the “Products” category for “Excellence in sustainability in laboratory and other high technology facilities”  The International Institute for Sustainable Laboratories (I2SL) runs a unique awards program honouring organisations, individuals, products,and projects that are advancing sustainable, high-performance facilities.

The pE-300ultra  offers triggering from multiple TTL inputs which, coupled with the ability to mount inline excitation filters, provides microsecond switching of pre-filtered excitation light.  This, when paired with today’s high performance multi-band filter sets, facilitates imaging traditionally done using a white light source and a filter wheel, with all the benefits of LED, and most excitingly at speeds not previously so affordable.

The system comprises a pE-300ultra Light Source, Control Pod, set of three Excitation Filter Holders and Power Supply.  It can be specified with a microscope adaptor for direct fit configuration or with a 3mm diameter liquid light guide if there is a need to keep the source of illumination remote from the microscope.  An optional pE-Universal Collimator and microscope adaptor can be selected for use with a liquid light guide.

A benefit of the pE-300ultra is that  stains can be viewed either individually or in combination, without filter cube changes.  This makes it ideal for use with multi-band filter sets as the screening process can be simplified when fewer filter cubes are used.  Independent control of the three LED channels means that the user can control the level of excitation of each fluorescent stain independently on a multi-stained sample, potentially removing the need for single band filter sets altogether. For further information on improved multi-stain testing, go to the Downloads tab.

An important additional feature of the pE-300ultra is that it includes CoolLED’s “Sequence Runner” multiple channel excitation mode.  Users can define the order of their fluorophore capture using their pE-300ultra Control Pod, then the pE-300ultra light source can accept a single TTL output from the experiment set-up’s camera to initiate the step-through of a sequence of excitation channels.  This feature is independent of the individual channel TTL inputs on the light source.  This offers users the facility to run through a sequence of excitation channels using a camera which has only a single TTL-out.

With an expected lifetime in excess of 25,000 on hours and a comprehensive range of microscope adaptors, the pE-300ultra can be fitted to most current and older microscopes and operate for many years without aligning or replacing bulbs. The result is a safe, convenient illumination system without any additional operating costs.

 

 

There are two pE-300ultra configuration options:

Direct-fit for connecting to a microscopes – by selecting from a range of microscope adaptors  which covers all current and most older models.  A simple once only adjustment will allow optimisation to the optical path of the microscope.

Liquid Light Guidewith a fixed 3mm diameter, liquid light guide.  An optional pE-Universal Collimator can be specified in conjunction with a microscope adaptor if required.

 

The pE-300ultra offers:

  • Clean bright illumination across the spectrum – excites common fluorescent stains
  • Specify for  existing single and multi-band filter sets – no need to buy new filters
  • Instant on/off – No shutters required, no warm up or cool down
  • Simple to fit, simple to use – no alignment, a once only adjustment
  • Stable & repeatable – reliable and consistent results
  • Wide range of microscope adaptors – fits most microscopes
  • Precise intensity control in 1% steps (0-100%) – no ND filters required
  • Excellent uniformity over field of view – fixed and stable, no alignment necessary
  • Long lifetime – expected to exceed 25,000 hours of operating time
  • Removable inline excitation filter holders – no moving parts
  • Individual channel triggering via TTL in microseconds
  • Sequence Runner – sequenced excitation from a single TTL-out

 

 

 

JNO-G(L)

JNOPTIC Filter JNO-G(L)

Download Catalog _ JNO-G(L)

– Filter set for TRITC / Cy3 Longpass
– Chroma Filter Model No. : 19004

JNO-G(L) Spectrum


JNO-G(L) Spectrum

Filters Type
AT540/25x EX
AT565DC BS
AT575lp EM

주요 형광 색소(Fluorochromes)와 스펙트럼 비교

* TRITC VS JNO-G(L)


JNO-G(L)필터를 이용한 Sample Image 촬영

Sample : bovine pulmonary artery endothelial cell, BPAEC
Filter Set : JNO-G(L)
Camera : AcquCAM 23GR2
C-mount adapter : 1X
Lens : UPLNAPO40X

Filter Set : JNO-G(L) Camera : AcquCAM 5G C-mount adapter : 1x Lens : UPLAPO40X Sample : bovine pulmonary artery endothelial cell, BPAEC

Sample : bovine pulmonary artery endothelial cell, BPAEC
Filter Set : JNO-G(L)
Camera : AcquCAM 5G
C-mount adapter : 1X
Lens : UPLNAPO40X


JNO-G(L)필터에 적합한 형광색소

  • R-phycoerythrin

JNO-G(L) Spec

  • Typical Application(s) : Widefield Microscopy
  • Coating : Sputter/Hard Coated
  • Round excitation and emission filters mounted in anodized aluminum rings 2.3mm thick, up to 25mm in diameter (for standard sizes)
  • Rectangular dichroics up to 26x38mm, 1mm thick, to fit standard microscope manufacturer filter cubes (for standard sizes)

*** For filters larger than 25mm and dichroics larger than 26x38mm, please contact us for pricing.

JNO-B(L)

JNOPTIC Filter JNO-B(L)

Download Catalog _ JNO-B(L)

– Filter set for GFP / FITC Longpass
– Chroma Filter Model No. : 19002

JNO-B(L) Spectrum

JNO-B(L) Spectrum

Filters Type
AT480/30x EX
 AT505DC BS
AT515lp EM

주요 형광 색소(Fluorochromes)와 스펙트럼 비교

 * FITC VS JNO-B(L)

FITC VS JNO-B(L)

 * GFP VS JNO-B(L)

GFP VS JNO-B(L)


JNO-B(L)필터를 이용한 Sample Image 촬영

Sample : bovine pulmonary artery endothelial cell, BPAEC
Filter Set : JNO-B(L)
Camera : AcquCAM 23GR2
C-mount adapter : 1X
Lens : UPLNAPO40X

Sample : bovine pulmonary artery endothelial cell, BPAEC Filter Set : JNO-B(L) Camera : AcquCAM 5G C-mount adapter : 1X Lens : UPLNAPO40X

Sample : bovine pulmonary artery endothelial cell, BPAEC Filter Set : JNO-B(L) Camera : AcquCAM 3G C-mount adapter : 1X Lens : UPLNAPO40X


  • Acridine Orange + DNA and RNA
  • Auramine-rhodamine
  • JC-1 non-ratiometric

JNO-B(L) Spec

  • Typical Application(s) : Widefield Microscopy
  • Coating : Sputter/Hard Coated
  • Round excitation and emission filters mounted in anodized aluminum rings 2.3mm thick, up to 25mm in diameter (for standard sizes)
  • Rectangular dichroics up to 26x38mm, 1mm thick, to fit standard microscope manufacturer filter cubes (for standard sizes)

*** For filters larger than 25mm and dichroics larger than 26x38mm, please contact us for pricing. 02-3473-4188~9

JNO-U(L)

JNOPTIC Filter  JNO-U(L)

Download Catalog _ JNO-U(L)

– Filter set for UV/DAPI Longpass
– Chroma Filter Model No. : 19000

JNO-U(L) Spectrum

JNO-U(L) Spectrum

Filters Type
AT375/28x EX
AT415DC BS
AT435lp EM

주요 형광 색소(Fluorochromes)와 스펙트럼 비교

* DAPI VS JNO-U(L)

DAPI VS JNO-U(L)


JNO-U(L)필터를 이용한 Sample Image 촬영

Sample : bovine pulmonary artery endothelial cell, BPAEC
Filter Set : JNO-U(L)
Camera : AcquCAM 23GR2
C-mount adapter : 1X
Lens : UPLNAPO40X

Sample : bovine pulmonary artery endothelial cell, BPAEC
Filter Set : JNO-U(L)
Camera : AcquCAM 5G
C-mount adapter : 1X
Lens : UPLNAPO40X

Sample : bovine pulmonary artery endothelial cell, BPAEC
Filter Set : JNO-U(L)
Camera : AcquCAM 3G
C-mount adapter : 1X
Lens : UPLNAPO40X


JNO-U(L)에 적합한 형광색소

  • Calcofluor White
  • DAPI

JNO-U(L) Spec

  • Typical Application(s) : Widefield Microscopy
  • Coating : Sputter/Hard Coated
  • Round excitation and emission filters mounted in anodized aluminum rings 2.3mm thick, up to 25mm in diameter (for standard sizes)
  • Rectangular dichroics up to 26x38mm, 1mm thick, to fit standard microscope manufacturer filter cubes (for standard sizes)

*** For filters larger than 25mm and dichroics larger than 26x38mm, please contact us for pricing.

JNO-R2(B)

JNOPTIC Filter  JNO-R2(B)

Download Catalog_JNO-R2(B)

– Filter set for Cy5 / AlexaFluor 647 / Draq5
– Chroma Filter Model No. : 39007

JNO-R2(B) Spectrum

Filters Type
 AT620/50x EX
AT655DC BS
AT690/50m EM

주요 형광 색소(Fluorochromes)와 스펙트럼 비교

* Cy5 VS JNO-R2(B)


Cy5 VS JNO-R2(B)

 * AlexaFluor 647 VS JNO-R2(B)

 * Draq5 VS JNO-R2 (B)


JNO-R2(B)필터에 적합한 형광색소


JNO-R2(B) Spec

  • Typical Application(s) : Widefield Microscopy
  • Coating : Sputter/Hard Coated
  • Round excitation and emission filters mounted in anodized aluminum rings 2.3mm thick, up to 25mm in diameter (for standard sizes)
  • Rectangular dichroics up to 26x38mm, 1mm thick, to fit standard microscope manufacturer filter cubes (for standard sizes)

*** For filters larger than 25mm and dichroics larger than 26x38mm, please contact us for pricing.